Skip to content
RESOLUTION ENGINEERING

RESOLUTION ENGINEERING

Menu
  • Home
  • Our Services
  • Projects
    • Structural Health Assessment
      • Visual inspection
      • Settlement Survey
      • Rebound hammer
      • Concrete Coring Test
      • Ferroscan test
      • Steel Tensile Test
      • Chemical anchor pull out testing
      • The Pull Out Test and The Shear Load Test on Anchor Bolts
      • Pull-off test
      • Parallel seismic test
      • Pile location detection
      • Air void location detection Test
      • Pile integrity test
      • Corrosion Test
      • Water permeability and concrete carbonation test
    • Floor/Building Vibration
      • Vibration Measurement and Dynamic Structural Analysis
      • Measurement of floor vibration caused by machines operation
      • Traffic induced vibration
      • Microelectronics fabrication facilities vibration measurement
      • Sensitive machine vibration measurement and vibration isolation problem
    • Load Test
      • Static Load Testing
      • Pull Out Test
    • Load Capacity Analysis
    • Geotechnique Exploration and Testing
  • Knowledge Transfer
    • Talks & Lectures
    • Publications
    • Blog
    • Our Clients
  • Contact us
  • Home
  • Our Services
  • Projects
    • Structural Health Assessment
      • Visual inspection
      • Settlement Survey
      • Rebound hammer
      • Concrete Coring Test
      • Ferroscan test
      • Steel Tensile Test
      • Chemical anchor pull out testing
      • The Pull Out Test and The Shear Load Test on Anchor Bolts
      • Pull-off test
      • Parallel seismic test
      • Pile location detection
      • Air void location detection Test
      • Pile integrity test
      • Corrosion Test
      • Water permeability and concrete carbonation test
    • Floor/Building Vibration
      • Vibration Measurement and Dynamic Structural Analysis
      • Measurement of floor vibration caused by machines operation
      • Traffic induced vibration
      • Microelectronics fabrication facilities vibration measurement
      • Sensitive machine vibration measurement and vibration isolation problem
    • Load Test
      • Static Load Testing
      • Pull Out Test
    • Load Capacity Analysis
    • Geotechnique Exploration and Testing
  • Knowledge Transfer
    • Talks & Lectures
    • Publications
    • Blog
    • Our Clients
  • Contact us

Tag: renovation

Tag: renovation

Steel roof structure load testing

November 20, 2017September 11, 2018resolutionLoad Carrying Capacity Analysis, Load Testing, Projectload testing, renovation, roof load testing, roof truss

The roof structure of a meeting room was insufficient for a new ceiling load requirement according to the FEM analysis. Thus, strengthening solution was provided, and a load test was carried out to verify the safety of the structure as this is a very important meeting room of an international organization.

© 2014 www.resolutionengineering.co.th
Hosting Supported by  Hostsevenplus